Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  844    845    846    847    848  849  850    851    852    853    854  
img
. . . . . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2204-08 Auxiliary Lever #1 Position
6. Turn the ignition switch and
Sensor Abnormal Frequency, Pulse
battery disconnect switch to
Width, or Period - Continued
the OFF position (TM 5-2410-
240-10).
7. Disconnect harness connec-
tor C-C12 (WP 0018, Figure
22) from PL-C1 (WP 0018,
Figure 214).
8. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 45 and harness con-
machine (TM 5-2410-240-10).
nector C-C49 (WP 0018, Fig-
Continuity - Proceed to step 9.
ure 36) terminal 1.
9. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 44 and harness con-
machine (TM 5-2410-240-10).
nector C-C49 (WP 0018, Fig-
Continuity - Proceed to step 10.
ure 36) terminal 2.
10. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 70 and harness con-
machine (TM 5-2410-240-10).
nector C-C49 (WP 0018, Fig-
Continuity - Proceed to step 11.
ure 36) terminal 3.
11. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 12.
between harness connector
Continuity - Replace lower cab
C-C12 (WP 0018, Figure 22)
harness (WP 0228). Ensure all
terminal 70 and all other termi-
harness connectors are recon-
nals in harness connector C-
nected. Verify proper operation of
C12 (WP 0018, Figure 22).
machine (TM 5-2410-240-10).
12. Disconnect harness connec-
tor PL-C4 (WP 0018, Figure
217) from equipment ECM J1.
13. Disconnect harness connec-
tor PL-C5 (WP 0018, Figure
218) from equipment ECM J2.