Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2204-04 Auxiliary Lever #1 Position
10. Using digital multimeter, test
No Continuity - Replace lower
Sensor Voltage Below Normal - Con-
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
tinued
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 70 and harness con-
machine (TM 5-2410-240-10).
nector C-C49 (WP 0018, Fig-
Continuity - Proceed to step 11.
ure 36) terminal 3.
11. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 12.
between harness connector
Continuity - Replace lower cab
C-C12 (WP 0018, Figure 22)
harness (WP 0228). Ensure all
terminal 70 and all other termi-
harness connectors are recon-
nals in harness connector C-
nected. Verify proper operation of
C12 (WP 0018, Figure 22).
machine (TM 5-2410-240-10).
12. Disconnect harness connec-
tor PL-C4 (WP 0018, Figure
217) from equipment ECM J1.
13. Disconnect harness connec-
tor PL-C5 (WP 0018, Figure
218) from equipment ECM J2.
14. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C4 (WP 0018, Figure 217)
nectors are reconnected. Verify
terminal 69 and harness con-
proper operation of machine (TM
nector PL-C1 (WP 0018, Fig-
5-2410-240-10).
ure 214) terminal 45.
Continuity - Proceed to step 15.
15. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C4 (WP 0018, Figure 217)
nectors are reconnected. Verify
terminal 56 and harness con-
proper operation of machine (TM
nector PL-C1 (WP 0018, Fig-
5-2410-240-10).
ure 214) terminal 44.
Continuity - Proceed to step 16.
16. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C5 (WP 0018, Figure 218)
nectors are reconnected. Verify
terminal 49 and harness con-
proper operation of machine
nector PL-C1 (WP 0018, Fig-
(TM 5-2410-240-10).
ure 214) terminal 70.
Continuity - Proceed to step 17.