Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  841    842    843    844    845  846  847    848    849    850    851  
img
. . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2204-04 Auxiliary Lever #1 Position
2. Disconnect harness connec-
Sensor Voltage Below Normal - Con-
tor C-C49 (WP 0018, Figure
tinued
36) from ripper joystick.
3. Turn battery disconnect switch
and ignition switch to ON posi-
tion (TM 5-2410-240-10).
4. Using digital multimeter, mea-
Voltage Less Than Specified
sure for voltage (WP 0283)
Range - Proceed to step 6.
between harness connector
Voltage Within Specified Range
C-C49 (WP 0018, Figure 36)
- Proceed to step 5.
terminal 1 and 2.
There should be approximately
10 volts 0.5 volts.
5. Using digital multimeter, mea-
Voltage Less Than Specified
sure for voltage (WP 0283)
Range - Proceed to step 6.
between harness connector
Voltage Within Specified Range
C-C49 (WP 0018, Figure 36)
- Replace ripper joystick (WP
terminal 2 and 3.
0218). Ensure all harness connec-
There should be approximately
tors are reconnected. Verify proper
5 volts 0.5 volts.
operation of machine (TM 5-2410-
240-10).
6. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
7. Disconnect harness connec-
tor C-C12 (WP 0018, Figure
22) from PL-C1 (WP 0018,
Figure 214).
8. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 45 and harness con-
machine (TM 5-2410-240-10).
nector C-C49 (WP 0018, Fig-
Continuity - Proceed to step 9.
ure 36) terminal 1.
9. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 44 and harness con-
machine (TM 5-2410-240-10).
nector C-C49 (WP 0018, Fig-
Continuity - Proceed to step 10.
ure 36) terminal 2.