• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  836    837    838    839    840  841  842    843    844    845    846  
img
. . . . . . . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2113-04 Operator In Seat Switch
5. Disconnect harness connec-
Voltage Below Normal - Continued
tor CA-C1 (WP 0018, Figure
69) from harness connector C-
C24 (WP 0018, Figure 26).
6. Using digital multimeter, test
No Continuity - Replace seat har-
for continuity (WP 0283)
ness (WP 0236). Ensure all har-
between harness connector
ness connectors are reconnected.
CA-C2 (WP 0018, Figure 70)
Verify proper operation of machine
terminal 3 and harness con-
(TM 5-2410-240-10).
nector CA-C11 (WP 0018, Fig-
Continuity - Proceed to step 7.
ure 75) terminal B.
7. Using digital multimeter, test
No Continuity - Replace seat har-
for continuity (WP 0283)
ness (WP 0236). Ensure all har-
between harness connector
ness connectors are reconnected.
CA-C2 (WP 0018, Figure 70)
Verify proper operation of machine
terminal 2 and harness con-
(TM 5-2410-240-10).
nector CA-C11 (WP 0018, Fig-
Continuity - Proceed to step 8.
ure 75) terminal C.
8. Using digital multimeter, test
No Continuity - Proceed to step 9.
for continuity (WP 0283)
Continuity - Replace seat harness
between harness connector
(WP 0236). Ensure all harness
CA-C2 (WP 0018, Figure 70)
connectors are reconnected. Verify
terminal 2 and all other termi-
proper operation of machine (TM
nals in harness connector CA-
5-2410-240-10).
C2 (WP 0018, Figure 70).
9. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 10.
between harness connector
Continuity - Replace seat harness
CA-C2 (WP 0018, Figure 70)
(WP 0236). Ensure all harness
terminal 3 and all other termi-
connectors are reconnected. Verify
nals in harness connector CA-
proper operation of machine (TM
C2 (WP 0018, Figure 70).
5-2410-240-10).
10. Disconnect harness connec-
tor C-C12 (WP 0018, Figure
22) from PL-C1 (WP 0018,
Figure 214).
11. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 2 and harness con-
machine (TM 5-2410-240-10).
nector C-C23 (WP 0018, Fig-
Continuity - Proceed to step 12.
ure 25) terminal 3.
0021-235


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.