TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2113-03 Operator In Seat Switch
Voltage Above Normal - Continued
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
nectors are reconnected. Verify
terminal 45 and harness con-
proper operation of machine (TM
5-2410-240-10).
ure 214) terminal 2.
ECM (WP 0147, WP 0149).
Ensure all harness connectors are
reconnected. Verify proper opera-
tion of machine (TM 5-2410-240-
10).
N OT E
2113-04 Operator In Seat Switch
Voltage Below Normal
Always inspect harness connectors that are involved in circuit.
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in circuit are clean and
secure, and connections are in good condition. If a problem with
connection is found, correct problem and verify diagnostic code
is active before performing this procedure.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
1. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
2. Disconnect harness connec-
75) from operator presence
Continuity Check Does Not
seat harness and operator
Agree With Expected Results -
Replace operator presence switch
Figure 195) for continuity (WP
(WP 0235). Ensure all harness
0283) between the following
connectors are reconnected. Verify
seat harness connector termi-
proper operation of machine (TM
nals:
5-2410-240-10).
a. Terminals A and B.
Continuity Check Agrees With
b. Terminals A and C. Refer
Expected Results - Proceed to
to Table 6 for results.
step 4.
4. Disconnect harness connec-
70) from harness connector C-