Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  851    852    853    854    855  856  857    858    859    860    861  
img
. . . . . . . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2305-04 Brake/Decelerator Pedal
8. Using digital multimeter, test
No Continuity - Replace lower
Position Sensor Voltage Below Nor-
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
mal - Continued
between harness connector P-
harness connectors are recon-
C1 (WP 0018, Figure 197) ter-
nected. Verify proper operation of
minal 9 and harness connec-
machine (TM 5-2410-240-10).
tor PC-8 (WP 0018, Figure
Continuity - Proceed to step 9.
202) terminal A.
9. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector P-
harness connectors are recon-
C1 (WP 0018, Figure 197) ter-
nected. Verify proper operation of
minal 10 and harness connec-
machine (TM 5-2410-240-10).
tor PC-8 (WP 0018, Figure
Continuity - Proceed to step 10.
202) terminal B.
10. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector P-
harness connectors are recon-
C1 (WP 0018, Figure 197) ter-
nected. Verify proper operation of
minal 11 and harness connec-
machine (TM 5-2410-240-10).
tor PC-8 (WP 0018, Figure
Continuity - Proceed to step 11.
202) terminal C.
11. Disconnect harness connec-
tor C-C12 (WP 0018, Figure
22) from PL-C1 (WP 0018,
Figure 214).
12. Disconnect harness connec-
tor C-C40 (WP 0018, Figure
30) from FP-C5 (WP 0018,
Figure 170).
13. Using digital multimeter WP
No Continuity - Proceed to
0283), test for continuity (WP
step 14.
0283) between harness con-
Continuity - Replace lower cab
nector P-C1 (WP 0018, Figure
harness (WP 0228). Ensure all
197) terminal 11 and all other
harness connectors are recon-
terminals in harness connec-
nected. Verify proper operation of
tor P-C1 (WP 0018, Figure
machine (TM 5-2410-240-10).
197).
14. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 35 and harness con-
machine (TM 5-2410-240-10).
nector C-C38 (WP 0018, Fig-
Continuity - Proceed to step 15.
ure 29) terminal 11.
0021-250


Privacy Statement
Press Release
Contact