Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  854    855    856    857    858  859  860    861    862    863    864  
img
. . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2305-08 Brake/Decelerator Pedal
2. Disconnect harness connec-
Position Sensor Abnormal Fre-
tor PC-8 (WP 0018, Figure
quency, Pulse Width Or Period -
202) from service brake posi-
Continued
tion sensor.
3. Turn battery disconnect switch
and ignition switch to ON posi-
tion (TM 5-2410-240-10).
4. Using digital multimeter, mea-
Voltage Less Than Specified
sure for voltage (WP 0283)
Range - Proceed to step 6.
between harness connector
Voltage Within Specified Range
PC-8 (WP 0018, Figure 202)
- Proceed to step 5.
terminal A and B.
There should be approximately
8 volts 0.5 volts.
5. Using digital multimeter, mea-
Voltage Less Than Specified
sure for voltage (WP 0283)
Range - Proceed to step 6.
between harness connector
Voltage Within Specified Range
PC-8 (WP 0018, Figure 202)
- Replace service brake position
terminal B and C.
sensor (WP 0243). Ensure all har-
There should be approximately
ness connectors are reconnected.
5 volts 0.5 volts.
Verify proper operation of machine
(TM 5-2410-240-10).
6. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
7. Disconnect harness connec-
tor C-C38 (WP 0018, Figure
29) from P-C1 (WP 0018, Fig-
ure 197).
8. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector P-
harness connectors are recon-
C1 (WP 0018, Figure 197) ter-
nected. Verify proper operation of
minal 1 and harness connec-
machine (TM 5-2410-240-10).
tor PC-8 (WP 0018, Figure
Continuity - Proceed to step 9.
202) terminal A.
9. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector P-
harness connectors are recon-
C1 (WP 0018, Figure 197) ter-
nected. Verify proper operation of
minal 2 and harness connec-
machine (TM 5-2410-240-10).
tor PC-8 (WP 0018, Figure
Continuity - Proceed to step 10.
202) terminal B.