Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2481-04 Winch Drive Away Switch
11. Using digital multimeter, test
No Continuity - Replace platform
Voltage Below Normal - Continued
for continuity (WP 0283)
harness (WP 0150, WP 0155).
between PL-C1 (WP 0018,
Ensure all harness connectors are
Figure 214) harness connec-
reconnected. Verify proper opera-
tor terminal 6 and PL-C4 (WP
tion of machine (TM 5-2410-240-
0018, Figure 217) equipment
10).
ECM J1 terminal 26.
Continuity - Proceed to step 12.
12. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
harness (WP 0150, WP 0155).
between PL-C1 (WP 0018,
Ensure all harness connectors are
Figure 214) harness connec-
reconnected. Verify proper opera-
tor terminal 5 and PL-C4 (WP
tion of machine (TM 5-2410-240-
0018, Figure 217) equipment
10).
ECM J1 terminal 27.
Continuity - Proceed to step 13.
13. Using digital multimeter, test
No Continuity - Proceed to step
for continuity (WP 0283)
14.
between PL-C4 (WP 0018,
Continuity - Replace platform har-
Figure 217) equipment ECM
ness (WP 0150, WP 0155).
J1 terminal 5 and all other ter-
Ensure all harness connectors are
minals in harness connector
reconnected. Verify proper opera-
PL-C4 (WP 0018, Figure 217).
tion of machine (TM 5-2410-240-
10).
14. Using digital multimeter, test
No Continuity - Replace machine
for continuity (WP 0283)
ECM (WP 0147, WP 0149).
between PL-C4 (WP 0018,
Ensure all harness connectors are
Figure 217) equipment ECM
reconnected. Verify proper opera-
J1 terminal 6 and all other ter-
tion of machine (TM 5-2410-240-
minals in harness connector
10).
PL-C4 (WP 0018, Figure 217).
Continuity - Replace platform har-
ness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper opera-
tion of machine (TM 5-2410-240-
10).