Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Left Door Wiper Does
Test Step 3.
Not Operate Properly
1. Disconnect left door wiper motor
Continued
harness connector LW-C2 (WP
0018, Figure 194) from left door
wiper motor.
2. Turn left door wiper/washer con-
trol to ON position (TM 5-2410-
240-10).
3. Using digital multimeter, test for
No Continuity - Proceed to step 4.
continuity (WP 0283) between left
Continuity - Proceed to step 6.
door wiper motor harness con-
nector LW-C2 (WP 0018, Figure
194) terminal 4 and cab ground.
4. Using digital multimeter, test for
No Continuity - Proceed to step 5.
continuity (WP 0283) between left
Continuity - Proceed to step 6.
door wiper motor harness con-
nector LW-C2 (WP 0018, Figure
194) terminal 2 and cab ground.
5. Using digital multimeter, test for
No Continuity - Replace left door
continuity (WP 0283) between left
wiper motor (WP 0209). Ensure all
door wiper motor harness con-
harness connectors are reconnected.
nector LW-C2 (WP 0018, Figure
Install a new #12 15A fuse (TM 5-
194) terminal 3 and cab ground.
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
Continuity - Proceed to step 6.
6. Disconnect harness connector
LW-C1 (WP 0018, Figure 193)
from harness connector PL-C24
(WP 0018, Figure 228).
7. Using digital multimeter, test for
No Continuity - Proceed to step 8.
continuity (WP 0283) between left
Continuity - Replace left door wiper
door wiper motor harness con-
motor jumper harness (WP 0209).
nector LW-C2 (WP 0018, Figure
Ensure all harness connectors are
194) terminal 4 and cab ground.
reconnected. Install a new #12 15A
fuse (TM 5-2410-240-10). Verify
proper operation of machine (TM 5-
2410-240-10).