TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0497-13 Blade Tilt Right
Test Step 1. Check for Active Cali-
bration Code.
machine control D6K ECM and
verify 0497-13 is active.
3. Check for active code 0497-13 in
Code 0497-13 Remains Active - Pro-
machine control D6K ECM (WP
ceed to Test Step 2.
Code 0497-13 Becomes Inactive -
Troubleshooting complete.
Test Step 2. Verify Machine Control
D6K ECM is Programmed Correctly.
1. Verify machine control D6K ECM
Software Correct - Replace machine
is flashed with correct software
ECM: with Ripper (WP 0147); with
Winch (WP 0149).
Proceed to step 2.
Software Incorrect - Flash machine
ECM with correct software (WP
2. Check for active code 0497-13 in
Code 0497-13 Active - Repeat trou-
machine control D6K ECM (WP
bleshooting code from the beginning.
Code 0497-13 Not Active - Trouble-
shooting complete.
N OT E
0498-03 Blade Tilt Left Sole-
noid Voltage Above Normal
Always inspect harness connectors thatare involved in the circuit. Poor
connections can often be the cause of an electrical circuit problem. Ver-
ify that all connections in circuit are clean and secure, and connections
are in good condition. If problem with connection is found, correct the
problem and verify diagnostic code is active before performing this pro-
cedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
Test Step 1. Test for Shorted Chas-
sis Wiring Harness.
machine control D6K ECM and
verify 0498-03 is active.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).