Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1039    1040    1041    1042    1043  1044  1045    1046    1047    1048    1049  
img
. . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1884-03 Winch Spool In
6. Using MSD (WP 0016), select
Code 1884-03 Active - Repeat trou-
Solenoid Voltage Above Nor-
machine control D6K ECM and
bleshooting code from the beginning.
mal - Continued
verify 1884-03 is not active.
Code 1884-03 Not Active - Trouble-
shooting complete.
Test Step 3. Test F869-PK Reel-In
Solenoid Supply Circuit for Short
to Other Circuits in Platform Wiring
Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).
3. Disconnect platform wiring har-
ness connector PL-C5 (WP 0018,
Figure 218) from ECM J2 (WP
0149).
4. Disconnect platform wiring har-
ness connector PL-C4 (WP 0018,
Figure 217) from ECM J1 (WP
0149).
5. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 6.
PL-C2 terminal 26 and all other
Continuity on One or More Test
circuits in PL-C2 (WP 0018, Fig-
Points - Replace platform wiring har-
ure 215).
ness (WP 0155).
Connect pump wiring harness con-
nector PH-C1 (WP 0018, Figure 205)
on engine wiring harness connector
EN-C21 (WP 0018, Figure 137) (WP
0046).
Install right side debris guards (WP
0187).
Proceed to step 8.