Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1037    1038    1039    1040    1041  1042  1043    1044    1045    1046    1047  
img
. . . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1198-13 Blade Raise Sole-
Test Step 1. Check for Active Cali-
noid Out of Calibration
bration Code.
1. Connect MSD (WP 0016). Select
machine control D6K ECM and
verify 1198-13 is active.
2. Perform calibration of blade raise
solenoid (WP 0033).
3. Check for active code 1198-13 in
Code 1198-13 Remains Active - Pro-
machine control D6K ECM (WP
ceed to Test Step 2.
0016).
Code 1198-13 Becomes Inactive -
Troubleshooting complete.
Test Step 2. Verify Machine Control
D6K ECM Is Programmed Correctly.
1. Verify machine control D6K ECM
Software Correct - Replace machine
is flashed with correct software
ECM: with Ripper (WP 0147); with
(WP 0017).
Winch (WP 0149).
Proceed to step 2.
Software Incorrect - Flash machine
ECM with correct software (WP
0017). Proceed to step 2.
2. Check for active code 1198-13 in
Code 1198-13 Active - Repeat trou-
machine control D6K ECM (WP
bleshooting code from the beginning.
0016).
Code 1198-13 Not Active - Trouble-
shooting complete.
N OT E
1884-03 Winch Spool In
Solenoid Voltage Above Nor-
Always inspect harness connectors thatare involved in the circuit. Poor
mal
connections can often be the cause of an electrical circuit problem. Ver-
ify that all connections in circuit are clean and secure, and connections
are in good condition. If a problem with a connection is found, correct
problem and verify diagnostic code is active before performing this pro-
cedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
Test Step 1. Test for Shorted Pump
Wiring Harness.
1. Connect MSD (WP 0016). Select
machine control D6K ECM and
verify 1884-03 is active.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
0023-80