• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1074    1075    1076    1077    1078  1079  1080    1081    1082    1083    1084  
img
. . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1885-05 Winch Spool Out
7. Check for active code 1885-05 or
Code 1885-05 Remains Active - Pro-
Solenoid Current Below Nor-
1885-06 in machine control D6K
ceed to Test Step 2.
mal - Continued
ECM (WP 0016).
Code 1885-05 Becomes Inactive
and 1885-06 Becomes Active - Turn
ignition switch and battery disconnect
switch to OFF position (TM 5-2410-
240-10).
Remove jumper wire from PH-C9 ter-
minal 1 and terminal 2 (WP 0018, Fig-
ure 213).
Replace reel-out solenoid (WP 0132).
Proceed to step 8.
8. Using MSD (WP 0016), select
Code 1885-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1885-05 is not active.
Code 1885-05 Not Active - Trouble-
shooting complete.
Test Step 2. Test for Open Pump
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove jumper wire from PH-C9
terminal 1 and terminal 2 (WP
0018, Figure 213).
3. Remove right side debris guards
from machine (WP 0187).
4. Disconnect pump wiring harness
connector PH-C1 (WP 0018, Fig-
ure 205) from engine wiring har-
ness connector EN-C21 (WP
0018, Figure 137) (WP 0046).
5. Connect jumper wire between
EN-C21 terminal 10 and terminal
12 (WP 0018, Figure 137).
6. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).