• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1069    1070    1071    1072    1073  1074  1075    1076    1077    1078    1079  
img
. . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1885-04 Winch Spool Out
3. Using digital multimeter (WP
No Continuity on Test Point - Pro-
Solenoid Voltage Below Nor-
0283), test for continuity between
ceed to Test Step 4.
mal - Continued
EN-C50 terminal 1 (WP 0018,
Continuity on Test Point - Replace
Figure 140) and ground.
engine wiring harness (WP 0046).
Connect pump wiring harness con-
nector PH-C9 on reel-out solenoid
(WP 0018, Figure 213) (WP 0267).
Install front floor plate on machine
(WP 0205).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 4.
4. Using MSD (WP 0016), select
Code 1885-04 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1885-04 is not active.
Code 1885-04 Not Active - Trouble-
shooting complete.
Test Step 4. J808-BK Reel-Out Sole-
noid Return Circuit for Short to
Other Circuits in Platform Wiring
Harness.
1. Remove right rear access cover
from machine (WP 0191).
2. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).
3. Disconnect platform wiring har-
ness connector PL-C5 (WP 0018,
Figure 218) from ECM J2 (WP
0149).
4. Disconnect platform wiring har-
ness connector PL-C4 (WP 0018,
Figure 217) from ECM J1 (WP
0149).