Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1068    1069    1070    1071    1072  1073  1074    1075    1076    1077    1078  
img
. . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1885-04 Winch Spool Out
7. Using digital multimeter (WP
No Continuity on Test Point - Pro-
Solenoid Voltage Below Nor-
0283), test for continuity between
ceed to Test Step 3.
mal - Continued
PH-C1 terminal 12 (WP 0018,
Continuity on Test Point - Replace
Figure 205) and ground.
pump wiring harness (WP 0046).
Proceed to step 8.
8. Using MSD (WP 0016), select
Code 1885-04 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1885-04 is not active.
Code 1885-04 Not Active - Trouble-
shooting complete.
Test Step 3. J808-BK Reel-Out Sole-
noid Return Circuit for Short to
Other Circuits in Engine Wiring
Harness.
1. Disconnect engine wiring har-
ness connector EN-C50 (WP
0018, Figure 140) from platform
wiring harness connector PL-C32
(WP 0018, Figure 232) (WP
0046).
2. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 3.
EN-C50 terminal 1 and all other
Continuity on One or More Test
circuits in EN-C50 (WP 0018, Fig-
Points - Replace engine wiring har-
ure 140).
ness (WP 0046).
Connect pump wiring harness con-
nector PH-C9 on reel-out solenoid
(WP 0018, Figure 213) (WP 0267).
Install front floor plate on machine
(WP 0205).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 4.