Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1140    1141    1142    1143    1144  1145  1146    1147    1148    1149    1150  
img
. . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2211-06 Auxiliary Valve #1
Test Step 3. Test J914-PU Ripper
Port B Solenoid Current
Lower Solenoid Circuit for Short to
Above Normal - Continued
Other Circuits in Platform Wiring
Harness.
1. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-2410-240-10).
2. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).
3. Disconnect platform wiring har-
ness connector PL-C5 (WP 0018,
Figure 218) from ECM J2: with
Ripper (WP 0147); with Winch
(WP 0149).
4. Disconnect platform wiring har-
ness connector PL-C4 (WP 0018,
Figure 217) from ECM J1: with
Ripper (WP 0147); with Winch
(WP 0149).
5. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 6.
PL-C2 terminal 42 and all other
Continuity on One or More Test
circuits in PL-C2 (WP 0018, Fig-
Points - Replace platform wiring har-
ure 215).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Connect chassis wiring harness con-
nector CH-C3 on auxiliary valve #1
port B solenoid (WP 0018, Figure 83).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 9.