• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1135    1136    1137    1138    1139  1140  1141    1142    1143    1144    1145  
img
. . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2211-05 Auxiliary Valve #1
7. Check for active code 2211-05 or
Code 2211-05 Remains Active - Pro-
Port B Solenoid Current
2211-06 in machine control D6K
ceed to Test Step 3.
Below Normal - Continued
ECM (WP 0016).
Code 2211-05 Becomes Inactive
and 2211-06 Becomes Active - Turn
ignition switch and battery disconnect
switch to OFF position (TM 5-2410-
240-10).
Remove jumper wire from PL-C18 ter-
minal 14 and terminal 15 (WP 0018,
Figure 226).
Replace chassis wiring harness: with
Ripper (WP 0153); with Winch (WP
0154).
Proceed to step 8.
8. Using MSD (WP 0016), select
Code 2211-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 2211-05 is not active.
Code 2211-05 Not Active - Trouble-
shooting complete.
Test Step 3. Test J914-PU Ripper
Lower Solenoid Circuit for High
Resistance or Open in Platform
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove jumper wire from PL-C18
terminal 14 and terminal 15 (WP
0018, Figure 226).
3. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).