Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1165    1166    1167    1168    1169  1170  1171    1172    1173    1174    1175  
img
. . . . . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2268-03 Winch Free Spool
5. Using digital multimeter (WP
No Continuity on Any Test Points -
Solenoid Voltage Above Nor-
0283), test for continuity between
Proceed to step 6.
mal - Continued
PL-C2 terminal 34 and all other
Continuity on One or More Test
circuits in PL-C2 (WP 0018, Fig-
Points - Replace platform wiring har-
ure 215).
ness (WP 0155).
Connect winch wiring harness con-
nector WF-C1 (WP 0018, Figure 253)
on winch solenoid wiring harness con-
nector WC-C3 (WP 0018, Figure 250)
(WP 0137).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 8.
6. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 7.
PL-C2 terminal 34 (WP 0018, Fig-
Continuity on One or More Test
ure 215) and all circuits in PL-C5
Points - Replace platform wiring har-
(WP 0018, Figure 218).
ness (WP 0155).
Connect winch wiring harness con-
nector WF-C1 (WP 0018, Figure 253)
on winch solenoid wiring harness con-
nector WC-C3 (WP 0018, Figure 250)
(WP 0137).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 8.
7. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to Test Step 4.
PL-C2 terminal 34 (WP 0018, Fig-
Continuity on One or More Test
ure 215) and all circuits in PL-C4
Points - Replace platform wiring har-
(WP 0018, Figure 217).
ness (WP 0155).
Connect winch wiring harness con-
nector WF-C1 (WP 0018, Figure 253)
on winch solenoid wiring harness con-
nector WC-C3 (WP 0018, Figure 250)
(WP 0137).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 8.
8. Using MSD (WP 0016), select
Code 2268-03 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 2268-03 is not active.
Code 2268-03 Not Active - Trouble-
shooting complete.
0023-208