TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2212-13 Auxiliary Valve #1
Test Step 1. Check for Active Cali-
bration Code.
bration
machine control D6K ECM and
verify 2212-13 is active.
valve #1 port A solenoid (WP
0033).
Code 2212-13 Remains Active - Pro-
3. Check for active code 2212-13 in
ceed to Test Step 2.
machine control D6K ECM (WP
Code 2212-13 Becomes Inactive -
Troubleshooting complete.
Test Step 2. Verify Equipment ECM
Is Programmed Correctly.
1. Verify equipment (Implement
Software Correct - Replace equip-
Control #2) ECM is flashed with
ment ECM (WP 0148).
Proceed to step 2.
Software Incorrect - Flash equip-
ment (Implement Control #2) ECM
ceed to step 2.
2. Check for active code 2212-13 in
Code 2212-13 Active - Repeat trou-
machine control D6K ECM (WP
bleshooting code from the beginning.
Code 2212-13 Not Active - Trouble-
shooting complete.
N OT E
2268-03 Winch Free Spool
Always inspect harness connectors thatare involved in the circuit. Poor
mal
connections can often be the cause of an electrical circuit problem. Ver-
ify that all connections in circuit are clean and secure, and connections
are in good condition. If problem with connection is found, correct the
problem and verify diagnostic code is active before performing this pro-
cedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.