Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1171    1172    1173    1174    1175  1176  1177    1178    1179    1180    1181  
img
. . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2268-04 Winch Free Spool
5. Inspect winch wiring harness for
No Damage Found - Proceed to
Solenoid Voltage Below Nor-
damage (WP 0283).
step 6.
mal - Continued
Damage Found - Replace winch wir-
ing harness (WP 0265).
Connect platform wiring harness con-
nector PL-C5 (WP 0018, Figure 218)
on ECM J2 (WP 0149).
Connect platform wiring harness con-
nector PL-C4 (WP 0018, Figure 217)
on ECM J1 (WP 0149).
Connect platform wiring harness con-
nector PL-C2 (WP 0018, Figure 215)
on equipment ECM (WP 0148).
Connect winch solenoid wiring har-
ness connector WC-C2 (WP 0018,
Figure 249) on platform wiring har-
ness connector PL-C33 (WP 0018,
Figure 233) (WP 0137).
Install right rear access cover on
machine (WP 0191).
Proceed to step 7.
0023-214