Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1172    1173    1174    1175    1176  1177  1178    1179    1180    1181    1182  
img
. . . . . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2268-04 Winch Free Spool
6. Using digital multimeter (WP
No Continuity on Any Test Points -
Solenoid Voltage Below Nor-
0283), test for continuity between
Replace free-spool solenoid (WP
mal - Continued
WF-C1 terminal 2 and all other
0266).
circuits in WF-C1 (WP 0018, Fig-
Connect platform wiring harness con-
ure 253).
nector PL-C5 (WP 0018, Figure 218)
on ECM J2 (WP 0155).
Connect platform wiring harness con-
nector PL-C4 (WP 0018, Figure 217)
on ECM J1 (WP 0155).
Connect platform wiring harness con-
nector PL-C2 (WP 0018, Figure 215)
on equipment ECM (WP 0148).
Connect winch solenoid wiring har-
ness connector WC-C2 (WP 0018,
Figure 249) on platform wiring har-
ness connector PL-C33 (WP 0018,
Figure 233) (WP 0137).
Install right rear access cover on
machine (WP 0191).
Proceed to step 7.
Continuity on One or More Test
Points - Replace winch wiring har-
ness (WP 0265).
Connect platform wiring harness con-
nector PL-C5 (WP 0018, Figure 218)
on ECM J2 (WP 0155).
Connect platform wiring harness con-
nector PL-C4 (WP 0018, Figure 217)
on ECM J1 (WP 0155).
Connect platform wiring harness con-
nector PL-C2 (WP 0018, Figure 215)
on equipment ECM (WP 0148).
Connect winch solenoid wiring har-
ness connector WC-C2 (WP 0018,
Figure 249) on platform wiring har-
ness connector PL-C33 (WP 0018,
Figure 233) (WP 0137).
Install right rear access cover on
machine (WP 0191).
Proceed to step 7.
7. Using MSD (WP 0016), select
Code 2268-04 Active - Replace
machine control D6K ECM and
equipment ECM (WP 0148).
verify 2268-04 is not active.
Code 2268-04 Not Active - Trouble-
shooting complete.
0023-215