TM 5-2410-240-23-1
0031
CROSSOVER RELIEF VALVE ADJUST CONTINUED
N OT E
One full turn of adjustment screw is equal to approximately 2,756 psi (19,002 kPa).
2. Loosen locknut (Figure 21, Item 1) and turn adjustment screw (Figure 21, Item 2). Use the following procedure
for adjustment:
a. Turn adjustment screw counterclockwise to decrease pressure. Turn adjustment screw 1/4 turn beyond
estimated adjustment position and then back to estimated adjustment position.
b. Turn adjustment screw clockwise to increase pressure.
3. Maintain position of adjustment screw (Figure 21, Item 2) as locknut (Figure 21, Item 1) is tightened.
Figure 21. Locknut and Adjustment Screw.
0031