Figure 1. Left Front Access Door and Fuel Shutoff Valve.
PRIME PUMP HOSE ASSEMBLY REPLACEMENT - Continued

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  290    291    292    293    294  295  296    297    298    299    300  
img
.
TM 5-2410-240-23-2
0069
REMOVAL CONTINUED
N OT E
Tag, mark, and note routing of prime pump hose to aid installation.
Cap all hose ends and fittings.
4. Position drain pan underneath machine.
5. Lift boot (Figure 2, Item 3), depress tab (Figure 2, Item 4), and disconnect prime pump hose (Figure 2, Item 1)
from connector (Figure 2, Item 2).
6. Lift boot (Figure 2, Item 3), depress tab (Figure 2, Item 4), and disconnect prime pump hose (Figure 2, Item 1)
from connector (Figure 2, Item 5).
Figure 2. Prime Pump Hose.