Figure 3. Ground Cable.
Figure 5. Battery Disconnect Switch.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  860    861    862    863    864  865  866    867    868    869    870  
img
.
TM 5-2410-240-23-2
0141
REMOVAL CONTINUED
N OT E
Tag and mark electrical connectors to aid installation.
5. Remove bolt (Figure 4, Item 1), washer (Figure 4, Item 5), and cables (Figure 4, Items 2 and 4) from machine
(Figure 4, Item 3).
Figure 4. Ground Cable.
0141
0141-4