TM 5-2410-240-23-2
0145
REMOVAL
000145
WARN I N G
Make sure master battery switch is in off position before replacing starter cables. Failure to
follow this warning may result in injury or death to personnel or damage to equipment.
N OT E
Tag and mark electrical connectors to aid installation.
1. Position boot (Figure 1, Item 6) aside.
2. Remove nut (Figure 1, Item 1), washer (Figure 1, Item 2), cable (Figure 1, Item 5), and washer (Figure 1,
Item 4) from junction box (Figure 1, Item 3).
Figure 1. Cable Connection at Junction Block.
0145