STARTER CABLE REPLACEMENT
Figure 2. Cable Retainer Underneath Right Side of Cab Floor.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  904    905    906    907    908  909  910    911    912    913    914  
img
.
TM 5-2410-240-23-2
0145
REMOVAL
000145
WARN I N G
Make sure master battery switch is in off position before replacing starter cables. Failure to
follow this warning may result in injury or death to personnel or damage to equipment.
N OT E
Tag and mark electrical connectors to aid installation.
1. Position boot (Figure 1, Item 6) aside.
2. Remove nut (Figure 1, Item 1), washer (Figure 1, Item 2), cable (Figure 1, Item 5), and washer (Figure 1,
Item 4) from junction box (Figure 1, Item 3).
Figure 1. Cable Connection at Junction Block.
0145