REMOVAL CONTINUED
N OT E
Note location of tiedown straps and tag and mark electrical connectors to aid installation.
16. Remove tiedown strap (Figure 8, Item 4) from three harness connectors (Figure 8, Item 7) and from clip
(Figure 8, Item 6). Discard tiedown strap.
17. Remove bolt (Figure 8, Item 2), washer (Figure 8, Item 3), clamp (Figure 8, Item 11), bracket (Figure 8,
Item 10), and spacer (Figure 8, Item 9) from bracket (Figure 8, Item 8).
18. Remove clamp (Figure 8, Item 11) from harness (Figure 8, Item 1).
19. Unlock and disconnect harness connector (Figure 8, Item 7) from connector cap (Figure 8, Item 5).