Figure 20. A/C Condenser Cover.
A/C THERMOSTATIC SWITCH REPLACEMENT

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  304    305    306    307    308  309  310    311    312    313    314  
img
. . .
TM 5-2410-240-23-3
0202
INSTALLATION CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Ensure any lifting device used is in good condition and of
suitable load capacity. Keep clear of heavy parts supported only by lifting device. Failure
to follow this warning may result in injury or death to personnel.
N OT E
Lift guide weighs approximately 100 lb (45 kg).
19. Attach sling and lifting device to lift guide (Figure 22, Item 1).
20. Using lifting device, install lift guide (Figure 22, Item 1) on machine.
21. Install four washers (Figure 22, Item 3) and bolts (Figure 22, Item 2).
Figure 22. Lift Guide.
0202
END OF TASK
FOLLOW-ON TASKS
000202
1. Install cab rear flood lamps (WP 0257).
2. Evacuate and recharge air conditioning system (WP 0254).
3. Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE