Figure 3. Filter Housing.
Figure 5. Filter Housing.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  308    309    310    311    312  313  314    315    316    317    318  
img
.
TM 5-2410-240-23-3
0203
INSTALLATION
000203
1. Install thermostatic switch (Figure 4, Item 5), two washers (Figure 4, Item 4), and screws (Figure 4, Item 3) on
air box (Figure 4, Item 7).
2. Install grommet (Figure 4, Item 2) on air box (Figure 4, Item 7).
N OT E
Handlethermostatic switch temperature probe with care. Thermostatic switch temperature
probe can be damaged if kinked or severely bent.
Install thermostatic switch temper ture probe as noted during removal.
a
3. With care, install thermostatic switch temperature probe (Figure 4, Item 1) in grommet (Figure 4, Item 2).
N OT E
Install connectors as noted during removal.
4. Connect two harness connectors (Figure 4, Item 6) to thermostatic switch (Figure 4, Item 5).
Figure 4. Filter Housing.
0203
0203-4