Figure 5. Cab Floor Plate Harness Connection.
Figure 8. Left Front Cab Mount Cover.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  566    567    568    569    570  571  572    573    574    575    576  
img
.
TM 5-2410-240-23-3
0232
REMOVAL CONTINUED
16. Disconnect two A/C hoses (Figure 6, Item 1) from A/C hoses (Figure 6, Item 2).
17. Turn two levers (Figure 6, Item 3) OFF at valves (Figure 6, Item 4).
18. Place a container to catch coolant under hoses (Figure 6, Item 6).
19. Loosen two clamps (Figure 6, Item 5) and remove two hoses (Figure 6, Item 6) from valves (Figure 6, Item 4).
Figure 6. Plenum Connections.
0232
20. Remove bolt (Figure 7, Item 2), washer (Figure 7, Item 3), clamp (Figure 7, Item 1), bracket (Figure 7, Item 4),
and spacer (Figure 7, Item 5) from operator platform (Figure 7, Item 6).
Figure 7. Wiring Harness Clamp.
0232