24. Install two spacers (Figure 14, Item 5), bracket (Figure 14, Item 4), clamp (Figure 14, Item 1), washer
(Figure 14, Item 3), and bolt (Figure 14, Item 2) on operator platform (Figure 14, Item 6).
Figure 14. Wiring Harness Clamp.
0232
25. Install two hoses (Figure 15, Item 6) and clamps (Figure 15, Item 5) on valves (Figure 15, Item 4).
26. Remove coolant container from under hoses (Figure 15, Item 6).
27. Turn two levers (Figure 15, Item 3) to ON position at valves (Figure 15, Item 4).
28. Connect two A/C hoses (Figure 15, Item 1) on A/C hoses (Figure 15, Item 2).
Figure 15. Plenum Connections.