TM 5-2410-240-23-3
0245
CLEANING AND INSPECTION
000245
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK
ASSEMBLY
000245
N OT E
Install wiring harness and tiedown straps as noted during removal.
1. Install two temperature sensors (Figure 22, Item 8) on case (Figure 22, Item 1).
2. Install duct connector (Figure 22, Item 11), four washers (Figure 22, Item 10), and bolts (Figure 22, Item 9) on
case (Figure 22, Item 1).
3. Install clip (Figure 22, Item 3) and bolt (Figure 22, Item 5) on case (Figure 22, Item 1).
4. Position wiring harness (Figure 22, Items 6 and 2) and install grommet (Figure 22, Item 7) on case (Figure 22,
Item 1).
5. Connect tiedown strap (Figure 22, Item 12) on wiring harness (Figure 22, Item 2).
6. Install new tiedown strap (Figure 22, Item 4) on clip (Figure 22, Item 3) and wiring harness (Figure 22, Item 2).
Figure 22. Wiring Harness and Duct Hose Connector.
0245