TM 5-2410-240-23-3
0245
ASSEMBLY CONTINUED
000245
N OT E
Install electrical connectors and tiedown straps as noted during removal.
7. Install blower motor resistor (Figure 23, Item 7) and two screws (Figure 23, Item 4) on case (Figure 23, Item 1).
8. Connect five connectors (Figure 23, Item 5) on blower motor resistor (Figure 23, Item 7).
9. Connect blower motor connector (Figure 23, Item 3) on harness connector (Figure 23, Item 2).
10. Install new tiedown strap (Figure 23, Item 8) on blower motor harness (Figure 23, Item 6) and wiring harness
(Figure 23, Item 9).
11. Connect tiedown strap (Figure 23, Item 10) on wiring harness (Figure 23, Item 9).
Figure 23. Blower Motor Resistor and Wiring Harness.
0245