Figure 1. Air Duct and Retaining Hardware.
HEATER HOSE REPLACEMENT

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  772    773    774    775    776  777  778    779    780    781    782  
img
.
TM 5-2410-240-23-3
0246
INSTALLATION
000246
1. Install three seals (Figure 1, Item 5) on air duct (Figure 1, Item 4).
2. Position air duct (Figure 1, Item 4) on machine.
3. Install two washers (Figure 1, Item 6), bolts (Figure 1, Item 7), and retaining air duct (Figure 1, Item 4) on
machine.
4. Install two washers (Figure 1, Item 2), bolts (Figure 1, Item 3), and retaining air duct (Figure 1, Item 4) on A/C
heater assembly (Figure 1, Item 1).
END OF TASK
FOLLOW-ON TASKS
000246
1. Install cab (WP 0232).
2. Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE