Figure 4. A/C Line, O-ring, and Retaining Hardware.
A/C LOW PRESSURE SENSOR REPLACEMENT
Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
838
839
840
841
842
843
844
845
846
847
848
TM
5-2410-240-23-3
0249
FOLLOW-ON TASKS
000249
1.
Install
right
engine
access
panel
(WP
0182)
and
debris
guards
(WP
0187)
.
2. Evacuate
and
recharge
A/C
system
(WP
0254).
3. Verify correct
operation
of
machine
(TM
5-2410-240-10).
END
OF
TASK
END
OF
WORK
PACKAGE
0249-7/(8