Table 1. Arctic Kit Troubleshooting Procedures for the D6K Dozer - Continued.
0273
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. ARCTIC KIT HEATER DOES 6. Inspect the accessory 15a
Fuse Open - Proceed to step 7.
NOT TURN ON CONTINUED
fuse (TM 5-2410-240-10)
Fuse OK - Resume normal
operation.
7. Disconnect platform wiring
harness connector PL-C3
(WP 0018, Figure 216)
from fuse panel connector
FP-C3 (Figure 168).
test for continuity between
breaker panel wiring harness
fuse panel connector
FP-C3 (Figure 168)
harness connectors are
reconnected and replace accessory
terminal 6 and machine
15a fuse (TM 5-2410-240-10).
ground.
No Continuity - Proceed to step 9.
There should be NO continuity.
9. Disconnect wiring harness
connector HW-C1
(WP 0018, Figure 189)
from wiring harness
connector PL-C7
(WP 0018, Figure 220).
test for continuity between
wiring harness (WP 0150 or WP
wiring harness connector
0155). Then ensure all harness
PL-C3 (WP 0018,
connectors are reconnected and
Figure 216) terminal 6 and
replace accessory 15a fuse
all other terminals in PL-C3
(TM 5-2410-240-10).
(WP 0018, Figure 216).
There should be NO continuity.
wiring harness (WP 0150 or WP
test for continuity between
0155). Then ensure all harness
wiring harness connector
connectors are reconnected and
PL-C3 (WP 0018,
replace accessory 15a fuse
Figure 216) terminal 6 and
(TM 5-2410-240-10).
machine ground.
No Continuity - Proceed to
There should be NO continuity.
step 12.
12. Disconnect wiring harness
connector AH-C3
(WP 0018, Figure 6) from
arctic kit heater
(WP 0018, Figure 9).