Table 1. Arctic Kit Troubleshooting Procedures for the D6K Dozer - Continued.
Table 1. Arctic Kit Troubleshooting Procedures for the D6K Dozer - Continued.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1044    1045    1046    1047    1048  1049  1050    1051    1052    1053    1054  
img
. .
TM 5-2410-240-23-3
0273
Table 1. Arctic Kit Troubleshooting Procedures for the D6K Dozer - Continued.
0273
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. ARCTIC KIT HEATER DOES  18. Using digital multimeter,
Continuity - Replace arctic kit
NOT TURN ON CONTINUED
test for continuity between
heater switch wiring harness (WP
wiring harness connector
0277). Then ensure all harness
AR-C2 (WP 0018,
connectors are reconnected and
Figure 11) terminal 2 and
replace accessory 15a fuse
machine ground.
(TM 5-2410-240-10).
No Continuity - Connect AR-C1
(WP 0018, Figure 10) on HW-C4
(WP 0018, Figure 192).
Connect AH-C3 (WP 0018,
Figure 6) on arctic kit heater
(WP 0018, Figure 9).
Connect HW-C1 (WP 0018,
Figure 189) on PL-C7 (WP 0018,
Figure 220).
Connect PL-C3 (WP 0018,
Figure 216) on FP-C3 (Figure 168).
Proceed to step 19.
19. Disconnect wiring harness
connector C-C4 (WP 0018,
Figure 16) from flood lamp
switch (WP 0018,
Figure 60).
20. Connect flood lamp switch
(WP 0018, Figure 60) on
wiring harness connector
AR-C2 (WP 0018,
Figure 11).
21. Install new accessory 15a
fuse (TM 5-2410-240-10).
22. Turn battery disconnect
switch to ON position
(TM 5-2410-240-10).
23. Turn flood lamp switch to
ON position (TM 5-2410-
240-10).
24. Turn flood lamp switch to
OFF position (TM 5-2410-
240-10).
25. Turn battery disconnect
switch to OFF position
(TM 5-2410-240-10).
0273-9