TM 5-2410-240-23-3
0273
Table 1. Arctic Kit Troubleshooting Procedures for the D6K Dozer - Continued.
0273
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. ARCTIC KIT HEATER DOES 18. Using digital multimeter,
NOT TURN ON CONTINUED
test for continuity between
heater switch wiring harness (WP
wiring harness connector
0277). Then ensure all harness
AR-C2 (WP 0018,
connectors are reconnected and
Figure 11) terminal 2 and
replace accessory 15a fuse
machine ground.
(TM 5-2410-240-10).
(WP 0018, Figure 10) on HW-C4
(WP 0018, Figure 192).
Connect AH-C3 (WP 0018,
Figure 6) on arctic kit heater
(WP 0018, Figure 9).
Connect HW-C1 (WP 0018,
Figure 189) on PL-C7 (WP 0018,
Figure 220).
Connect PL-C3 (WP 0018,
Figure 216) on FP-C3 (Figure 168).
Proceed to step 19.
19. Disconnect wiring harness
connector C-C4 (WP 0018,
Figure 16) from flood lamp
switch (WP 0018,
Figure 60).
20. Connect flood lamp switch
(WP 0018, Figure 60) on
wiring harness connector
AR-C2 (WP 0018,
Figure 11).
21. Install new accessory 15a
fuse (TM 5-2410-240-10).
22. Turn battery disconnect
switch to ON position
(TM 5-2410-240-10).
23. Turn flood lamp switch to
ON position (TM 5-2410-
240-10).
24. Turn flood lamp switch to
OFF position (TM 5-2410-
240-10).
25. Turn battery disconnect
switch to OFF position
(TM 5-2410-240-10).
0273-9