MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. ARCTIC KIT HEATER DOES  5. Using digital multimeter,
Continuity - Proceed to step 6.
NOT TURN ON CONTINUED
test for continuity between
No Continuity - Replace arctic kit
wiring harness connector
heater wiring harness (WP 0277).
HW-C3 (WP 0018, Figure
Then ensure all harness connectors
191) terminal 3 and wiring
are reconnected.
harness connector HW-C4
(WP 0018, Figure 192)
terminal 3.
6. Disconnect wiring harness
connector AR-C2
(WP 0018, Figure 11) from
arctic kit heater switch
(WP 0018, Figure 12)
(WP 0277).
7. Using digital multimeter,
Continuity - Proceed to step 8.
test for continuity between
No Continuity - Replace arctic kit
wiring harness connector
heater switch wiring harness
AR-C2 (WP 0018, Figure 5)
(WP 0277). Then ensure all
terminal 3 and AR-C1
harness connectors are
(WP 0018, Figure 10)
reconnected.
terminal 3.
8. Using digital multimeter,
Continuity - Proceed to step 9.
test for continuity between
No Continuity - Replace arctic kit
wiring harness connector
heater switch wiring harness
AR-C2 (WP 0018, Figure 5)
(WP 0277). Then ensure all
terminal 2 and AR-C1
harness connectors are
(WP 0018, Figure 10)
reconnected.
terminal 1.
9. With the arctic kit heater
No Continuity - Replace arctic kit
switch in ON position (TM
heater switch (WP 0277). Then
5-2410-240-10), test for
ensure all harness connectors are
continuity between arctic kit
reconnected.
heater switch (WP 0018,
Continuity - Proceed to step 10.
Figure 12) terminal 2 and
terminal 3.
There should be continuity.
10. Turn battery disconnect
switch to ON position
(TM 5-2410-240-10).