TM 5-2410-240-23-3
0278
ARCTIC HEATER REMOVAL CONTINUED
N OT E
Tag electrical connectors to aid installation.
2. Disconnect arctic heater connector (Figure 2, Item 1) from arctic heater (Figure 2, Item 2).
WARN I N G
Diesel fuel is combustible and an irritant. Skinand eye protection is required. Ensure work
area is well ventilated.
Keep away from open flame and other ignition sources.
Fuel leaked or spilled onto ho surfaces or electrical components can cause a fire.
t
Failure to follow these warnings may result in injury or death to personnel.
N OT E
Tag hoses to aid installation.
3. Remove tiedown strap (Figure 2, Item 5) from hoses. Discard tiedown strap.
4. Remove clamp (Figure 2, Item 3) and fuel hose (Figure 2, Item 4) from arctic heater (Figure 2, Item 2).
5. Remove clamp (Figure 2, Item 7) and hose (Figure 2, Item 6) from arctic heater (Figure 2, Item 2).
Figure 2. Arctic Heater Attachments.
0278