Figure 9. Water Inlet Hose Routing.
Figure 11. Water Outlet Hose Clamp.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1116    1117    1118    1119    1120  1121  1122    1123    1124    1125    1126  
img
.
TM 5-2410-240-23-3
0279
INSTALLATION CONTINUED
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may cause injury to personnel.
8. Apply sealing compound on fitting (Figure 10, Item 3) and install on cylinder head (Figure 10, Item 1).
N OT E
Install hoses as tagged during removal.
9. Install hose (Figure 10, Item 4) and clamp (Figure 10, Item 2) on fitting (Figure 10, Item 3).
Figure 10. Water Outlet Hose.
0279
0279-11