Figure 10. Water Outlet Hose.
Figure 12. Hose from Radiator Routing.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1117    1118    1119    1120    1121  1122  1123    1124    1125    1126    1127  
img
.
TM 5-2410-240-23-3
0279
INSTALLATION CONTINUED
N OT E
Route hose between secondary fuel filter and oil fill tube.
10. Install clamp (Figure 11, Item 3) on hose (Figure 11, Item 5).
11. Install clamp (Figure 11, Item 3), washer (Figure 11, Item 2), and bolt (Figure 11, Item 1) on primary fuel filter
base (Figure 11, Item 4).
Figure 11. Water Outlet Hose Clamp.
0279
0279-12