10
TM 5-2410-240-23-3
0285
FIELD MAINTENANCE
-
TORQUE LIMITS
0285
SCOPE
000285
This work package lists standard torque values and provides general information for applying torque. Special
torque values and tightening sequences are indicated in the maintenance procedures for applicable components.
GENERAL
000285
1. Always use torque values listed in Tables 1 and 2 when a maintenance procedure does not give a specific
torque value.
a. Table 1 provides torque limits for SAE-standard fasteners.
b. Table 2 provides torque limits for metric fasteners.
2. Unless otherwise indicated, standard torque tolerance shall be 10 percent.
3. If the maintenance procedures do not specify a tightening order, use the following guidelines:
a. Unless otherwise specified, lightly lubricate threads and mating surface of the head on fasteners with
clean oil (OE/HDO-10).
b. When tightening fasteners above 30 lb-ft (41 Nm), use the torque pattern given, but tighten to only 70
percent of final value (multiply final value by 0.7). Repeat pattern until final value is reached.
c.
Tighten circular patterns using circular torque pattern and tighten straight patterns using straight torque
pattern.
1
8
5
12
10
4
3
11
9
6
7
2
CIRCULAR TORQUE PATTERN
4
6
8
9
7
5
3
1
2
STRAIGHT TORQUE PATTERN
C AU T I O N
If replacement capscrews are of a higher grade than those originally supplied, use the
torque specifications for the original. This will prevent equipment damage due to
overtorquing.