Figure 23. Tow Pin.
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued

Operators Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  145    146    147    148    149  150  151    152    153    154    155  
img
. .
TM 5-2410-241-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
0012
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL HOURS
61  After
Hydraulic Tank a. Check hydraulic fluid level on
Hydraulic fluid level is low.
(Cont.)
Sight Gauge
sight gauge.
b. Clean area around hydraulic
tank filler cap and slowly remove
hydraulic tank filler cap.
c. Add hydraulic fluid (WP 0022,
Items 11, 12, or 13) to maintain level
between FULL mark and ADD mark
on sight gauge. Refer to LO 5-2410-
241-13 for proper oil based on
outside temperature.
d. Install hydraulic tank filler cap.