Figure 38. Guard, Plate, and Retaining Hardware.
Figure 40. Guard, Plate, and Retaining Hardware.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  584    585    586    587    588  589  590    591    592    593    594  
img
. . .
TM 5-2410-241-23-1
0020
Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1401-5 Transmission Sole-
1. Connect MSD (WP 0016), select
1. If active 1401-5 code is present,
noid Valve #1 Voltage
Powertrain D7 ECM, and check for
proceed to step 2.
Below Normal
Diagnostic Codes (WP 0013).
2. If no active codes are present, the
problem does NOT exist at this
time. Resume normal operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
3. Remove four bolts (Figure 39,
Item 2), washers (Figure 39,
Item 3), and guard (Figure 39,
Item 1) from machine.
Figure 39. Guard and Retaining Hardware.
0020