TM 5-2410-241-23-1
0020
Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1402-6 Transmission Sole-
18. Remove rear floor plate (WP
noid Valve #2 Current
0231).
Above Normal - Contin-
ued
19. Disconnect platform harness con-
53) from transmission jumper har-
Figure 54).
1. If continuity is found, proceed to
0296), test for continuity between
step 21.
pin 2 on platform harness connec-
tor to transmission jumper harness
platform harness (WP 0209).
Ensure all harness connectors are
pin 29 on platform harness con-
reconnected. Verify correct opera-
tion of machine (TM 5-2410-241-
Figure 33).
10).
1. If continuity is found, proceed to
0296), test for continuity between
step 22.
pin 6 on platform harness connec-
tor to transmission jumper harness
platform harness (WP 0209).
Ensure all harness connectors are
pin 30 on platform harness con-
reconnected. Verify correct opera-
tion of machine (TM 5-2410-241-
Figure 33).
10).
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 23.
pin 29 on platform harness con-
form harness (WP 0209). Ensure
33) and all other pins in platform
all harness connectors are recon-
harness connector MA-C14 (WP
nected. Verify correct operation of
machine (TM 5-2410-241-10).
23. Disconnect transmission jumper
harness connector MP-C1 (WP
0018, Figure 55) from transmis-
sion harness connector P-C1 (WP
1. If continuity is found, proceed to
0296), test for continuity between
step 25.
pin 2 on transmission jumper har-
transmission jumper harness (WP
Figure 54) and pin F on transmis-
0169). Ensure all harness connec-
sion jumper harness connector
tors are reconnected. Verify cor-
rect operation of machine (TM 5-
2410-241-10).
0020-180