Table 2. Chassis Troubleshooting Procedures - Continued.
Table 2. Chassis Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  703    704    705    706    707  708  709    710    711    712    713  
img
. . . . . . . . . . . . . . .
TM 5-2410-241-23-1
0021
Table 2. Chassis Troubleshooting Procedures - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
882-5 Hydraulic Lockout
18. Using digital multimeter (WP
1.
If continuity is found, proceed to
Solenoid Current Below
0296) test for continuity between
step 19.
Normal - Continued
pin 1 on platform harness connec- 2.
If continuity is NOT found, replace
tor MA-C17 (WP 0018, Figure 85)
platform harness (WP 0209).
and pin 51 on platform harness
Ensure all harness connectors
MA-C14 (WP 0018, Figure 33).
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
19. Using digital multimeter (WP
1. If continuity is NOT found, pro-
0296) test for continuity between
ceed to step 20.
pin 51 on platform harness con-
2. If continuity is found, replace plat-
nector MA-C14 (WP 0018, Figure
form harness (WP 0209). Ensure
33) and all other pins in platform
all harness connectors are recon-
harness connector MA-C14 (WP
nected. Verify correct operation of
0018, Figure 33).
machine (TM 5-2410-241-10).
20. Using digital multimeter (WP
1. If continuity is found, proceed to
0296) test for continuity between
step 21.
pin 51 on platform harness con-
2. If continuity is NOT found, replace
nector MA-C14 (WP 0018, Figure
platform harness (WP 0209).
33) and pin 11 on RH platform
Ensure all harness connectors
harness connector MA-C1 (WP
are reconnected. Verify correct
0018, Figure 15).
operation of machine (TM 5-2410-
241-10).
21. Using digital multimeter (WP
1.
If continuity is found, proceed to
0296) test for continuity between
step 22.
pin 64 on platform harness con-
2.
If continuity is NOT found, replace
nector MA-C14 (WP 0018, Figure
platform harness (WP 0209).
33) and pin 8 on RH platform har-
Ensure all harness connectors
ness connector MA-C1 (WP
are reconnected. Verify correct
0018, Figure 15).
operation of machine (TM 5-2410-
241-10).
22. Using digital multimeter (WP
1. If continuity is NOT found, pro-
0296) test for continuity between
ceed to step 23.
pin 64 on platform harness con-
2. If continuity is found, replace plat-
nector MA-C14(WP 0018, Figure
form harness (WP 0209). Ensure
33) and all other pins in platform
all harness connectors are recon-
harness connector MA-C14 (WP
nected. Verify correct operation of
0018, Figure 33).
machine (TM 5-2410-241-10).
23. Disconnect RH console harness
hydraulic lockout switch connec-
tor RW-C7 (WP 0018, Figure 89)
from hydraulic lockout switch (WP
0208).
0021-42