Table 1. Cab Troubleshooting Procedures - Continued.
Table 1. Cab Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  715    716    717    718    719  720  721    722    723    724    725  
img
. . . . . . . .
TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Front Cylinder Mounted
27. Inspect inside of right front cylin-
1. If corrosion or damage is found,
Flood Lamp(s) Do Not
der-mounted flood lamp for corro-
replace right front cylinder-
Work - Continued
sion and damage.
mounted flood lamp assembly
(WP 0210). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
2. If corrosion and damage is NOT
found, proceed to step 28.
28. Using digital multimeter (WP
1. If continuity is found, proceed to
0296), test for continuity between
step 29.
pin 1 and terminal 4 on right front
2. If continuity is NOT found, replace
cylinder-mounted flood lamp (WP
right front cylinder-mounted flood
0018, Figure 180).
lamp assembly (WP 0210).
Ensure all harness connectors
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
29. Using digital multimeter (WP
1. If continuity is found, replace right
0296), test for continuity between
front cylinder-mounted flood lamp
pin 2 and terminal 3 on right front
bulb (WP 0216). Ensure all har-
cylinder-mounted flood lamp (WP
ness connectors are reconnected.
0018, Figure 180).
Verify correct operation of
machine (TM 5-2410-241-10).
2. If continuity is NOT found, replace
right front cylinder-mounted flood
lamp assembly (WP 0216).
Ensure all harness connectors
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
30. Turn main light switch to OFF
position (TM 5-2410-241-10).
31. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
32. Open right front grille door (WP
0156).
33. Disconnect right front flood lamp
harness connector GC-C1 (WP
0018, Figure 96) from front light-
ing harness connector G-C3 (WP
0018, Figure 97).
0022-5