TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Front Cylinder Mounted
1.
Flood Lamp(s) Do Not
0296), test for continuity between
step 35.
Work - Continued
pin 1 on right front flood lamp har- 2.
right front flood lamp harness (WP
0018, Figure 96) and pin 1 on
0154). Ensure all harness con-
right front cylinder-mounted flood
nectors are reconnected. Verify
lamp harness connector GC-C2
correct operation of machine (TM
5-2410-241-10).
1.
0296), test for continuity between
lighting harness (WP 0167).
pin 2 on right front flood lamp har-
Ensure all harness connectors
are reconnected. Verify correct
0018, Figure 96) and pin 2 on
operation of machine (TM 5-2410-
right front cylinder-mounted flood
241-10).
lamp harness connector GC-C2
2.
right front flood lamp harness (WP
0154). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
36. Turn main light switch to OFF
position (TM 5-2410-241-10).
37. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
38. Disconnect right front cylinder-
mounted flood lamp harness con-
93) from right front cylinder-
mounted flood lamp.
39. Disconnect left front cylinder-
mounted flood lamp harness con-
92) from left front cylinder-
mounted flood lamp.
40. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-241-10).
41. Turn main light switch to Head-
light position (TM 5-2410-241-10).
1. If 24 Volts is found, proceed to
0296), measure for voltage
step 43.
between pin 1 and 2 on right front
2. If 24 Volts is NOT found, proceed
cylinder-mounted flood lamp har-
to step 54.
0022-6