Table 1. Cab Troubleshooting Procedures - Continued.
Table 1. Cab Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  719    720    721    722    723  724  725    726    727    728    729  
img
. . .
TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Front Cylinder Mounted
56. Remove Fuse #8 (Figure 1,
Flood Lamp(s) Do Not
Item 1) from fuse panel (TM 5-
Work - Continued
2410-241-10).
Figure 1. Fuse #8.
0022
57. Using a digital multimeter (WP
1. If continuity is NOT found, replace
0296), test for continuity between
Fuse #8 (TM 5-2410-241-10) and
blades of Fuse #8.
proceed to step 58.
2. If continuity is found, install Fuse
#8 on fuse panel (TM 5-2410-241-
10). Proceed to step 66.
58. Connect right front cylinder-
mounted flood lamp harness con-
nector GC-C2 (WP 0018, Figure
93) to right front cylinder-mounted
flood lamp.
59. Connect left front cylinder-
mounted flood lamp harness con-
nector GA-C2 (WP 0018, Figure
92) to left front cylinder-mounted
flood lamp.
60. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-241-10).
1. If front cylinder mounted flood
61. Turn main light switch to Head-
lamps do NOT operate, proceed
light position (TM 5-2410-241-10).
to step 62.
Observe front cylinder-mounted
2. If front cylinder-mounted flood
flood lamps.
lamps operate, resume normal
operation (TM 5-2410-241-10).
0022-9