MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Ether Aid Does NOT Work -
10. Using digital multimeter (WP
1. If 24 Volts is found, replace ether
Continued
0296), measure for voltage
aid solenoid (WP 0060). Ensure
between pins 1 and 2 on engine
all harness connectors are recon-
harness ether injector solenoid
nected. Verify correct operation of
connector V-C2 (WP 0018, Figure
machine (TM 5-2410-241-10).
179).
2. If 24 Volts is NOT found, proceed
to step 11.
11. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
12. Remove digital multimeter
(WP 0296) leads from Plug 1 and
Plug 2 on engine harness ether
injector solenoid connector V-C2
(WP 0018, Figure 179).
13. Remove Fuse #1 (Figure 19,
Item 1) from fuse panel (TM 5-
2410-241-10).
Figure 19. Fuse #1
0022
14. Using digital multimeter (WP
1. If continuity is found, install Fuse
0296), test for continuity between
#1 on fuse panel (TM 5-2410-241-
blades of Fuse #1.
10). Proceed to step 22.
2. If continuity is NOT found, replace
Fuse #1 (TM 5-2410-241-10).
Proceed to step 15.