Figure 2. Right Side Mount.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1071    1072    1073    1074    1075  1076  1077    1078    1079    1080    1081  
img
.
TM 5-2410-241-23-1
0044
REMOVAL
00044
C AU T I O N
Cap all A/C lines and fittings during removal to protect against contamination. Failure to
follow this caution may result in equipment damage.
N OT E
Tag A/C lines to aid installation.
1. Loosen tube nut (Figure 1, Item 1) and remove line (Figure 1, Item 4) from condenser (Figure 1, Item 2).
2. Remove O-ring (Figure 1, Item 3) from line (Figure 1, Item 4). Discard O-ring.
Figure 1. Lower A/C Line.